Temperature meter
- Technical data

Measuring range:
  • Semiconductor sensor -20...+150 °C
Electrical connection:
  • Terminals and cable gland M20x1.5
  • Souriau connector type 845, size 1
  • Hirschmann connector type G4
  • Fixed cable connection: type of cable LiYCY
Process connection, sensor:
  • Thread G½
  • Selectable length of sensor in the range of 30...1000 mm
Output signal:
  • Frequency 5-15 Hz
  • Two-wire technology 4-20 mA
Housing:
  • Stainless steel
  • Connection head TEM-EX-L****1A*******: Plastic
  • Connectors: metal and plastic
Power supply:
  • 0.8...30,0 V DC (with external power limitation)
  • 0.8...18.5 V DC
  • 0.8...13.5 V DC
Current consumption:20 mA
Protection acc. to EN 60529:IP65
Marking acc. to 2014/34/EU (ATEX):I M1 Ex ia I MA (KDB 08ATEX027)
Ambient temperature:
  • Standard: -20...+70 °C
  • Fixed cable connection:
    • -5...+70 °C (occasional flexing)
    • -20...+70 °C (fixed installed)
Process temperature:-20...+150 °C
Measuring uncertainty:
  • Max. +/- 0.2 K in the temperature range: -20...+60 °C
  • Max. +/- 0.5 % from the end value in the temperature range: +60...+150 °C

 

Subject to change without notice!