Pressure meter
- Technical data

Measuring range:
  • Max. 600 bar (thinfilm)
  • Max. 60 bar (ceramic diaphragm)
  • Other measuring ranges are available on request
Electrical connection:
  • Terminals and cable gland M20x1.5
  • Fixed cable connection: type of cable LiYCY, standard length 3 m (other types and lengths on request)
  • Machaczek connector type ME2A
  • PROMOS connector type BN4160
  • Hydrostar connector type SKK24
  • Binder connector series 723
  • Souriau connector series 845
  • Hirschmann connector type G4A5M
Output signal:
  • Frequency 5-15 Hz
  • Voltage 1-5 V
  • Voltage 1-10 V
Process connection, sensor:
  • Pipe thread G1¼, flush-mounted ceramic sensor
  • Pipe thread G½, internal ceramic sensor
  • Pipe thread G½, flush-mounted thinfilm sensor
  • Pipe thread G½, internal thinfilm sensor
  • Socket nipple DN10 (acc. to DIN 20043), thinfilm sensor
  • Pipe/vessel flange
Housing:
  • Stainless steel
  • Connection head PEMEX-LC**K*: Plastic
Power supply:
  • PEMEX-LC*L*: max. 12.5 V DC
  • PEMEX-LC*H*: max. 18.5 V DC
Current consumption:9 mA
Protection acc. to EN 60529:IP65
Marking acc. to 2014/34/EU (ATEX):I M1 EEx ia I (DMT 02 ATEX E 213)
MA Safety Certificate:

MFB21035J, valid for

  • PEMEX-LCUHSDID060b10V
Ambient temperature:-20...+60 °C
Process temperature:-20...+60 °C
Measuring uncertainty:Max. ± 1 % of end value, typ. ± 0.5 % of end value

 

Subject to change without notice!

Contact person

If you have any questions about our pressure meter PEMEX‑LC, please contact:

Ingo Weichert (Graduate engineer)

P +49 2102 955-725
F +49 2102 955-720
E ingo.weichert(at)kirchgaesser.com
B Business card (vcf)

Kirchgaesser Industrieelektronik GmbH | Am Rosenbaum 6 | D-40882 Ratingen | +49 2102 9556 |
Imprint | Privacy policy | Sitemap