Pressure meter with local display
- Technical data

Measuring range:
  • Max. 600 bar (thinfilm)
  • Max. 60 bar (ceramic diaphragm)
  • Other measuring ranges are available on request
Electrical connection:
  • Terminals and cable glands M20x1.5
  • PROMOS connector type BN4160
  • Hydrostar connector type SKK24
  • Becker module and terminals
  • Souriau connector series 845
Output signal:
  • Frequency 5-15 Hz
  • Limit
Versions available:
  • Evaluation unit and transducer combined in a single housing
  • Evaluation unit with remote transducer
  • Evaluation unit with extended transducer
  • Evaluation unit with hydrostatic transducer
Process connection, sensor:
  • Pipe thread G1¼, flush-mounted ceramic sensor
  • Pipe thread G½, internal ceramic sensor
  • Pipe thread G½, flush-mounted thinfilm sensor
  • Pipe thread G½, internal thinfilm sensor
  • Socket nipple DN10 (acc. to DIN 20043), thinfilm sensor
  • Pipe/vessel flange
Housing:Stainless steel
Power supply:
  • PEMEX-E**L*: 8.0...12.5 V DC
  • PEMEX-E**H*: 10.0...18.5 V DC
Current consumption:30 mA
Protection acc. to EN 60529:IP65
Marking acc. to 2014/34/EU (ATEX):I M1 EEx ia I (DMT 03 ATEX E 063)
Ambient temperature:-20...+60 °C
Process temperature:-20...+60 °C
Measuring uncertainty:Max. ± 1 % of end value, typ. ± 0.5 % of end value

 

Subject to change without notice!

Contact person

If you have any questions about our pressure meter PEMEX‑E, please contact:

Ingo Weichert (Graduate engineer)

P +49 2102 955-725
F +49 2102 955-720
E ingo.weichert(at)kirchgaesser.com
B Business card (vcf)

Kirchgaesser Industrieelektronik GmbH | Am Rosenbaum 6 | D-40882 Ratingen | +49 2102 9556 |