| Measuring range: | - Max. 600 bar (thinfilm)
- Max. 60 bar (ceramic diaphragm)
- Other measuring ranges are available on request
|
| Electrical connection: | - Terminals and cable gland M20x1.5
- Souriau connector type 845, size 1
- Hirschmann connector type G4
- Fixed cable connection: type of cable LiYCY
|
| Output signal: | - Frequency 5-15 Hz
- Two-wire technology 4-20 mA
|
| Process connection, sensor: | - Pipe thread G¼, sensor: internal thinfilm
- Pipe thread G½, sensor: internal thinfilm
- Pipe thread G½, sensor: internal ceramic
- Pipe thread G½, sensor: flush-mounted thinfilm
- Pipe thread G1¼, sensor: flush-mounted ceramic
- Plug-in sleeve DN6, sensor: thinfilm
- Flange DN40 PN6 with extension, sensor: flush-mounted ceramic
- Hydrostatic transducer
|
| Housing: | - Stainless steel 1.4301
- Connection head PEM-EX-L***A*****1**: Plastic
- Connectors: metal and plastic
|
| Power supply: | - 8.0...30.0 V DC (with external power limitation)
- 8.0...18.5 V DC
- 8.0...13.5 V DC
|
| Current consumption: | 20 mA |
| Protection acc. to EN 60529: | IP65 |
| Marking acc. to 2014/34/EU (ATEX): | I M1 Ex ia I MA (KDB 08ATEX027) |
| Ambient temperature: | - Standard: -20...+70 °C
- Fixed cable connection:
- -5...+70 °C (occasional flexing)
- -20...+70 °C (fixed installed)
|
| Process temperature: | -20...+70 °C |
| Measuring uncertainty: | Max. ± 1 % of end value, typ. ± 0.5 % of end value |