Level meter
- Technical data

Measuring range:Max. 10 m for solids and max. 20 m for liquids
Output signal:
  • Frequency 5-15 Hz
  • Current 4-20 mA
  • And one additional potential-free optocoupler output
Electrical connection (connectors each with a cable gland):
  • Terminals with two cable gland M25x1.5
  • Machaczek connector type ME2A10
  • PROMOS connector type BN4160
  • Hydrostar connector type SKK24 or SKK45M
  • Souriau connector series 845 (size 1 or 2)
  • Hirschmann connector type G4A5M
  • Circular connector M12
Housing:Glasfibre-reinforced polyester, graphite added
Power supply:Max. 13.5 V DC (range depending on transducer and output signal)
Current consumption:60 mA
Protection of the housing acc. to EN 60529:IP65
Marking acc. to 2014/34/EU (ATEX):I M2 Ex ia I (KDB 09ATEX146)
Ambient temperature:
  • Transducer LEVEL-EX-S: -20...+70 °C
  • Evaluation and display unit LEVEL-EX-A: -20...+50 °C
Ambient pressure:0.8...1.1 bar abs.
Process pressure:0.7...3 bar abs.
Measuring uncertainty:± 1 % of the adjusted measuring distance
Sampling rate:Max. 2 Hz

 

Subject to change without notice!

Contact person

If you have any questions about our level meter LEVEL‑EX, please contact:

Michael Kuhrig (Graduate engineer FH)

P +49 2102 955-715
F +49 2102 955-720
E michael.kuhrig(at)kirchgaesser.com
V Visitenkarte (vcf)

Kirchgaesser Industrieelektronik GmbH | Am Rosenbaum 6 | D-40882 Ratingen | +49 2102 9556 |