| Measuring principle: | Electromagnetic |
| Flow measuring ranges: | Programmable (in ranges of the nominal width, see additional information) |
| Nominal width: | DN50 to DN300 (optional with high pressure couplings, like SSKV heavy version) |
| Nominal pressure ranges: | 10 bar (1 MPa) to 500 bar (50 MPa) |
| Electrical connection: |
|
| Output signal: | Up to 4 programmable outputs:
|
| Input: | Turn down (weekend input) |
| Housing: | Stainless steel |
| Electrode material: | 1.4571 (316Ti) |
| Bolt circle of the flanges according to: | EN 1092-1 |
| Power supply: | 9.0...13.0 V DC |
| Current consumption: | 500 mA |
| Protection acc. to EN 60529: | IP65 |
| Marking acc. to 2014/34/EU (ATEX): | I M2 Ex ia I Mb (DMT 02 ATEX E 115) |
| Ambient temperature: | Max. +60 °C |
| Process temperature: | -20...+60 °C |
| Measuring uncertainty: | Max. ± 1 % of end value, typ. ± 0.5 % of end value |
Subject to change without notice!
If you have any questions about our electromagnetic large flow meter MIDEX, please contact:
Ingo Weichert (Graduate engineer)
P +49 2102 955-725
F +49 2102 955-720
E ingo.weichert(at)kirchgaesser.com
B Business card (vcf)