Measuring principle: | Electromagnetic |
Flow measuring ranges: | 0...100 l/min (DN50) to 0...1000 l/min (DN150) and 0...10 m³/h (DN50) to 0...2000 m³/h (DN300) respectively |
Nominal widths: | DN50 to DN300 (optional with high pressure couplings, like SSKV heavy version) |
Nominal pressure ranges: | 10 bar (1 MPa) to 500 bar (50 MPa) |
Electrical connection: | Hirschmann connector type G4 |
Output signal: | Provided by the Kirchgaesser evaluation and/or display unit COMBA-EX |
Housing: | Steel and stainless steel |
Electrode material: | 1.4571 (316Ti) |
Bolt circle of the flanges according to: | EN 1092-1 |
Power supply: | Provided by the Kirchgaesser evaluation and/or display unit COMBA-EX |
Current consumption: | 480 mA |
Protection acc. to EN 60529: | IP65 |
Marking acc. to 2014/34/EU (ATEX): | I M1 Ex ia I (BVS 09 ATEX E 020) |
Ambient temperature: | -20...+60 °C |
Process temperature: | -20...+60 °C |
Measuring uncertainty: | Max. ± 1 % of end value, typ. ± 0.5 % of end value |
Subject to change without notice!
If you have any questions about our electromagnetic large flow transducer MID‑EX‑GC, please contact:
Ingo Weichert (Graduate engineer)
P +49 2102 955-725
F +49 2102 955-720
E ingo.weichert(at)kirchgaesser.com
B Business card (vcf)