Microwave barrier
- Technical data

Detection range:Max. 100 m
Operating frequency:24.15 GHz ± 80 MHz
Electrical connection:
  • Cable gland M20
  • Thread ANSI ½ NPT
  • Binder connector type M12 series 713/763
  • Harting connector type HAN8D
Output signal:
  • Relay SPDT
  • Current 4-20 mA
  • Solid-state relay
Power supply:
  • 85...253 V AC, 50/60 Hz
  • 20...60 V DC or 20...30 V AC, 50/60 Hz
Housing:
  • Polyester
  • Aluminum
  • Stainless steel 316L
Process connection:
  • Thread R 1½ in accordance with EN 10226
  • Thread G 1½ in accordance with ISO 228-1
  • Thread 1½ NPT in accordance with ANSI/ASME
Optional process connection:
  • Flange
  • Sight glass
  • High-temperature adapter
  • High-pressure adapter
  • Mounting bracket
  • Structured accessories FAR50, FAR51, FAR52, FAR53, FAR54 and FAR55
  • Individual customer solutions
Main wetted parts:
  • Contactless installation: no
  • Mounting: 316Ti or Aluminum, PTFE or ceramic
Ambient temperature:-40...+70 °C
Process temperature:
  • Contactless installation: any
  • Mounting: -40...+70 °C, with high-temperature adapter -40... +450 °C
Process pressure:
  • Contactless installation: any
  • Mounting: 0.5...6.8 bar (50...680 kPa) abs., with high-pressure adapter 0.5...21 bar (50...2100 kPa) abs.
Protection acc. to EN 60529:IP66
Vibration resistance - Endurance stress
with sliding frequency acc. to
EN 60068-2-6:
  • Excitation mode: sine
  • Frequency range: 10...55 Hz
  • Amplitude: 0.75 mm peak constant
  • Speed of sweep: 1 oct / min
  • Excitation direction: 3 directions (X, Y, Z)
  • Number of cycles: 20 / direction
  • Test duration: approx. 1 h 38 min / direction
  • Test temperature: room temperature
Marking acc. to 2014/34/EU (ATEX):ATEX II 1/2D Ex ta/tb IIIC T200 102°C Da/Db, ATEX II 2D Ex tb IIIC T200 102°C Db (BVS 11 ATEX E 032 X)
Marking acc. to IECEx:Ex ta/tb IIIC T102°C Da/Db IP66, Ex tb IIIC T102°C Db IP66 (IECEx BVS 11.0016)
Marking acc. to CSA:
  • CSA C/US General Purpose (2668182)
  • CSA C/US Class II, Div. 1, Group E-G (2609701)
Marking acc. to EAC Ex:
  • EAC Ex ta/tb IIIC T102°C Da/Db, EAC Ex tb IIIC T102°C Db (RU C-DE.AA87.B.01096)
Radio approval:
  • Directive 2014/53/EU (RED)
  • FCC
  • IC

 

Subject to change without notice!

Contact person

If you have any questions about our microwave barrier FQR56/FDR56, please contact:

Michael Kuhrig (Graduate engineer FH)

P +49 2102 955-715
F +49 2102 955-720
E michael.kuhrig(at)kirchgaesser.com
B Business card (vcf)

 

Hanno Kirchgaesser (Graduate engineer)

P +49 2102 955-6
F +49 2102 955-720
E hanno.kirchgaesser(at)kirchgaesser.com
B Business card (vcf)

Kirchgaesser Industrieelektronik GmbH | Am Rosenbaum 6 | D-40882 Ratingen | +49 2102 9556 |
Imprint | Privacy policy | Sitemap