| Measuring range: | Max. 42 m |
| Output signal: | 0/4-20 mA active 2 (optional 4) relay outputs, freely assigned e.g. counting pulse, reset pulse, maintenance, run-up, upper limit position, alarm or measurement active |
| Inputs: | 2 freely assigned, selectable active/passive |
| Power supply: |
|
| Ambient temperature: | -40...+60 °C |
| Process temperature: | -20...+150 °C |
| Process pressure: | 0.8...1.1 bar absolut |
| Process connection: | DN 100, PN 16 (dimensions acc. to EN 1092-1) |
| Protection acc. to EN 60529: | IP67 |
| Marking acc. to 2014/34/EU (ATEX): | ATEX II 1/2D Ex ta/tb IIIC T99°C Da/Db IP6X ATEX II 2D Ex tb IIIC T99°C Db IP6X (BVS 05 ATEX E 001) |
| Measuring uncertainty: | +/- 1 Impuls or +/- 2.5 cm |
Subject to change without notice!
If you have any questions about our electromechanical level meter FMM20, please contact:
Michael Kuhrig (Graduate engineer FH)
P +49 2102 955-715
F +49 2102 955-720
E michael.kuhrig(at)kirchgaesser.com