| Detection range: | Max. 20 m |
| Operating frequency: | 24.15 GHz ± 80 MHz |
| Electrical connection: | - Cable gland M20
- Thread ANSI ½ NPT
- Binder connector type M12 series 713/763
- Harting connector type HAN8D
|
| Output signal: | - Relay SPDT
- Current 4-20 mA
- Solid-state relay
|
| Power supply: | - 85...253 V AC, 50/60 Hz
- 20...60 V DC or 20...30 V AC, 50/60 Hz
|
| Housing: | - Polyester
- Aluminum
- Stainless steel 316L
|
| Process connection: | - Thread R 1½ in accordance with EN 10226
- Thread G 1½ in accordance with ISO 228-1
- Thread 1½ NPT in accordance with ANSI/ASME
|
| Optional process connection: | - Flange
- Sight glass
- High-temperature adapter
- High-pressure adapter
- Mounting bracket
- Structured accessories FAR50, FAR51, FAR52, FAR53, FAR54 and FAR55
- Individual customer solutions
|
| Main wetted parts: | - Contactless installation: no
- Mounting: 316Ti or Aluminum, PTFE or ceramic
|
| Ambient temperature: | -40...70 °C |
| Process temperature: | - Contactless installation: any
- Mounting: -40...+70 °C, with high-temperature adapter -40... +450 °C
|
| Process pressure: | - Contactless installation: any
- Mounting: 0.5...6.8 bar (50...680 kPa) abs., with high-pressure adapter 0.5...21 bar (50...2100 kPa) abs.
|
| Protection acc. to EN 60529: | IP66 |
Vibration resistance - Endurance stress with sliding frequency acc. to EN 60068-2-6: | - Excitation mode: sine
- Frequency range: 10...55 Hz
- Amplitude: 0.75 mm peak constant
- Speed of sweep: 1 oct / min
- Excitation direction: 3 directions (X, Y, Z)
- Number of cycles: 20 / direction
- Test duration: approx. 1 h 38 min / direction
- Test temperature: room temperature
|
| Marking acc. to 2014/34/EU (ATEX): | ATEX II 1/2D Ex ta/tb IIIC T200 102°C Da/Db, ATEX II 2D Ex tb IIIC T200 102°C Db (BVS 11 ATEX E 032 X) |
| Marking acc. to IECEx: | Ex ta/tb IIIC T102°C Da/Db IP66, Ex tb IIIC T102°C Db IP66 (IECEx BVS 11.0016) |
| Marking acc. to CSA: | - CSA C/US General Purpose (2668182)
- CSA C/US Class II, Div. 1, Group E-G (2609701)
|
| Marking acc. to EAC Ex: | - EAC Ex ta/tb IIIC T102°C Da/Db, EAC Ex tb IIIC T102°C Db (RU C-DE.AA87.B.01096)
|
| Radio approval: | - Richtlinie 2014/53/EU (RED)
- FCC
- IC
|